How to solve MB SD Compact C4 EWA Session Token expired Error 46

                                                                              How to solve MB SD Compact C4 EWA Session Token expired Error 462?

2016.7 MB SD Compact C4 with software benz vediamo 5.00.05 released. V2016.7 MB SD C4 diagnosis software  with super mercedes-benz sd connect C4 can works for almost of benz vehicle till 2016 year. Do you know how to solve MB SD C4 software EWA Session Token expired Error? Where can buy Mercedes-Benz DTS software?
2016.7 mb compact c4 mb sd c4
Error:Tested many solutions for SD connect c4 software - EPC/WIS shortcut (EPC 09.2014). After 8-10 minutes work NOT the shortcut, EWA net error 462 - expired.
2016.7 mb sd c4 software

Solution:
ind and edit this file: C:/programm files/EWA net/config/um_cfg.xml
Find this line:
30
and change 30 to -1 .
And in this line:
480
change 480 to -1 .
 
If the solution does not work, try:
1)Delete the EPC application from Java in Control Panel.
2)Run the fix.
3) From EWA Admin Tool ---> Restart EWA server service ---> Stop EWA database ---> Start EWA database. (Or you can simply restart your computer).
4) From EWA net shotcut ---> Make sure that you have a valid key ---> Log on and Start EPC.
5)Close EPC and EWA net (Internet Browser).
6)Create EPC shortcut from Java in Control Panel.
After this make new EPC&WIS shortcut (from JAVA) and this shortcut will never expire.